Hardware Needed:
STRATIS Tablet
CO/CT cable
Mini USB cable
Ensure that the tablet is connected to internet.
Select Door Operations via the shortcut on the STRATIS homepage.
Select Download Door Files.
Select the units to be downloaded.
The blue triangle on the left of the unit group lets you view units within the group.
The blue plus sign lets you select an entire unit group or an individual unit.
Select Download.
Attach the CO/CT cable to the mini usb adapter and plug it into the tablet.
Select Yes if the tablet asks you to use the USB device.
Under Connect to Locks, select CO/CT.
Plug the CO/CT cable into the bottom of the CO200.
Press the Schlage button located at the top of the CO200 twice to put the lock into programming mode.
Select Set Door Time if prompted, otherwise select Program Door.
The rablet will pull an audit from the lock and then program the lock with updated door files. When complete, the Lock Programmed Successfully message will appear.